A reverse osmosis unit rarely fails with a loud alarm. The membrane gets slower, lets more dissolved material through, and sends more water to the drain, and each change is small enough to explain away. This guide covers what to measure, which changes matter, and what to ask before the water tastes wrong.

Set a baseline while the unit is fresh

The most useful check is the one you make when the unit is new or freshly serviced. Fill a measured container from the RO faucet with the storage tank full, and note how long it takes. Then, with a handheld TDS meter, record two readings: one from the cold feed line before the unit, and one from the RO faucet. Write these down in a simple log with the starting point at the top. A baseline you can compare against is worth far more than any single reading.

Watch the fill time

After the storage tank empties, watch how long it takes to refill. Use the same container, the same faucet, and the same starting condition each time. A slow refill can come from a membrane that is wearing out, but it can also come from a clogged pre-filter, low feed pressure, or a storage tank that has lost its air charge. Check the pre-filters and the tank before you blame the membrane.

Read the drain line

The drain should run while the unit is making water and stop once the storage tank is full. A steady drain flow with the faucet closed points to a restrictor, an auto shutoff valve, or a leak somewhere in the line. A drain that stops completely while the faucet is open points to a blockage or a valve problem. If the drain suddenly runs heavier than before while output drops, look at the membrane and the restrictor together, since they affect each other.

Compare the TDS and the taste

A rising TDS reading at the RO faucet, measured against your baseline, is the clearest sign that the membrane is passing more dissolved material. Taste changes can come from the same source, but they can also come from an exhausted post-filter or a dirty storage tank, and taste alone will not tell you which. Log both, and note whether the change came on gradually or all at once. A sudden change shortly after a service visit points toward a seal, a fitting, or an installation issue. A gradual change points toward normal wear.

What to ask your provider

Before the next visit, ask these questions and write down the answers:

Which membrane is installed, and can they give you the model and part number in writing?

What readings do they record at each visit, and will they give you the numbers, not just a pass or fail?

What triggers a membrane replacement in their process, a measured reading, a fixed schedule, or both?

Do pre-filter changes happen on the same visit as the membrane check, or are they separate charges?

If the membrane needs replacing under warranty, who covers the labor, and who confirms the result with a reading afterward?

When to stop using the water and call

If you see water leaking from the housing, a drain that floods or backs up, or a taste or odor that is clearly wrong, close the unit's feed valve and use another drinking water source until a provider has checked the system. Do not wait for the next scheduled visit to report a problem you can already see.